Home > SHOP ALL PRODUCTS > Power Supplies > DC power supplies >

Sorensen XFR600-4 DC Power Supply, 0-600 V, 0-4 A, 2400 W.

Sorensen XFR600-4 DC Power Supply, 0-600 V, 0-4 A, 2400 W. New in Box
Sorensen XFR600-4 DC Power Supply, 0-600 V, 0-4 A, 2400 W. New in Box.
 
List Price: $7,469.67 US Dollars


Availability: Ask for availability +1 (619) 879-6696
Product Code: XFR 600-4
 

Description
 
Features
XFR Series : Zero Voltage "Soft" Switching
 

XFR is the smart choice for research, product development and production test applications such as R&D, magnet control, product design, ATE, process control, electroplating and burn-in. The unique features of XFR make it the best choice for OEM applications where high power and a wide adjustment of output voltage or current are required in a full 19-inch rack package. Choose from twenty 2800-watt and 1200-watt models.

Zero voltage, or "soft" switching, provides significant benefits. Switching transients are virtually eliminated and noise performance is closer to linear levels. Efficiency is increased, heat generation is decreased, and stress on the switching transistors is reduced - improving reliability (MTBF). Unlike most competitive products, XFR generates full power at full rated current over its total operating range of 0 to 50° C without derating. XFR is also designed with excellent thermal management, so units can be stacked in rack mounts without leaving ventilation space between each unit. The low thermal generation and high efficiency of "soft" switching technology allows for the packaging of 1200 watts in a 1.75-inch (1 U) high, 19-inch rack mount chassis, providing 20% more power than any competitive product in the same size package.
 

Key Features

  • Analog programming
  • Constant voltage or constant current operation
  • LabView® and LabWindows® drivers
  • Standby mode
  • Front panel button preview of voltage, current, OVP
  • CE, CSA, UL approvals

Electrical Specifications 1

 

Output Ratings:

 

 

 

Output Voltage

 

0-600 V

 

Output Current

 

0-4 A

 

Output Power

 

2400 W

 

Line Regulation: 2

 

 

 

Voltage (0.01% of Vmax + 2 mV)

 

15 mV

 

Current (0.01% of Imax + 2 mA)

 

3 mA

 

Load Regulation: 3

 

 

 

Voltage (0.02% of Vmax + 5 mV)

 

15 mV

 

Current (0.02% of Imax + 5 mA)

 

3 mA

 

Meter Accuracy:

 

 

 

Voltage (0.5% of Vmax + 1 count)

 

7 V

 

Current (0.5% of Imax + 1 count)

 

0.05 A

 

Output Noise & Ripple:

 

 

 

Voltage rms

 

35 mV

 

Voltage (p-p) (0-20 MHz)

 

175 mV

 

Current rms

 

3 mA

 

Drift (8 hours): 4

 

 

 

Voltage (0.05% of Vmax)

 

300 mV

 

Current (0.05% of Imax)

 

2 mA

 

Temperature coefficient: 5

 

 

 

Voltage (0.02% of Vmax/° C)

 

120 mV

 

Current (0.03% of Imax/° C)

 

1.2 mA

 

Program Slew Rate: 6

 

 

 

Rise Time

 

170 ms

 

Fall Time

 

170 ms

 

OVP adjustment range: (5% to 110% of Vmax)

 

30-660 V

 

Efficiency: 7

 

91%

 

Interface Specifications 1,8

 

Program Resolution (16-bit):

 

 

 

Voltage

 

10.1 mV

 

Current

 

0.07 mA

 

OVP

 

10.1 mV

 

Program Accuracy:

 

 

 

Voltage (0.2% + 10 mV)

 

300 mV (+/- 0.35%)

 

Current (0.3% + 10 mA)

 

80 mA (+/- 0.1%)

 

OVP (0.5% + 100 mV)

 

6000 mV

 

Readback Resolution (16-bit):

 

 

 

Voltage

 

10.1 mV

 

Current

 

0.07 mA

 

Readback Accuracy:

 

 

 

Voltage (0.2% + 20 mV)

 

300 mV (+/- 0.35%)

 

Current (0.3% + 20 mA)

 

80 mA (+/- 0.1%)

 

 

 

 

 

1. Specifications indicate typical performance at 25 ° C +/- 5° C, nominal line input of 120 VAC.

 

2. For input voltage variation over the AC input voltage range, with constant rated load.

 

3. For 0-100% load variation, with constant nominal line voltage.

 

4. Maximum drift over 8 hours with constant line, load and temperature, after 30 minute warm-up.

 

5. Change in output per ° C change in ambient temperature, with constant line and load.

 

6. Measured at full rated output with a resistive load.

 


7. Typical efficiency at 200 VAC input and rated output power.

8. Apply accuracy specifications according to the following voltage program accuracy example:
    Set a model 20-130 power supply to 10 volts. The expected result will be within the range of 10 volts +/- 75 mV +/-
    0.12% of the set voltage of 10 volts.

 

 

 

General Specifications

 

Operational AC input voltage

 

190-264 VAC, 1 phase (24.3 A @ 208 VAC; 20.5 A @ 230 VAC typical), 47-63 Hz; Option: M2 3-phase 208 VAC input.

 

Switching Frequency

 

Nominal 31 kHz (62 kHz output ripple)

 

Time Delay

 

7 s maximum from power on until output stable

 

Voltage Mode Transient Response Time

 

<3 ms for output voltage to recover within 0.5 % of its rated voltage after a step change in load current of up to 10% to 90% of rated output

 

Maximum Voltage Differential

 

+/-600 VDC from output to safety ground

 

Remote On/Off and Interlock

 

2.5-15 V signal or TTL-compatible input, selectable logic

 

Remote Analog Programming

 

Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances;0-5 V, 0-10 V (default) voltage sources

 

Remote Analog Monitoring

 

Voltage and current monitor outputs 0-5 V, 0-10 V (default) ranges for 0-100% of output

 

Remote Programming and Monitoring Accuracy

 

1% zero to full scale output for the default range

 

Maximum Remote Sense Line Drop Compensation

 

5 V/line (Line drop is subtracted from total voltage available at supply output)

 

Operating Temperature Range

 

32° F to 122 ° F (0° C to 50° C)

 

Storage Temperature Range

 

-4° F to 158° F (-20° C to 70° C)

 

Humidity Range

 

Up to 90% RH, non-condensing

 

Front Panel Voltage and Current Control

 

10-turn voltage and current potentiometers

 

Front Panel Voltage Control Resolution

 

0.02% of maximum voltage

 

AC Input Connector Type

 

3-terminal, 34 A/250 V, wire clamp connector with strain relief cover

 

Main Output Connector

 

7.5 to 100 V models: nickel-plated copper bus bars with bus bar cover and strain relief;150 V to 600 V models: 4-terminal, wire clamp connector with cover and strain relief

 

Weight (one unit)

 

33 lb (15 kg) approx

 

Dimensions (H x W x D)

 

3.5 x 19.0 x 21.0” (88.9 x 429.4 x 533.5 mm)

 

Options

 

GPIB-XFR3

 

GPIB Interface card (16-bit)

 

HFS-XFR3

 

Fiber Optic Serial Interface card (16-bit)

 

RS-232-XFR3

 

RS-232 Interface card (16-bit)

 

ISOL-XFR3

 

ISOL Interface card provides isolated analog control and readback

 

ISOL-420

 

4-20 mA isolated analog control

 

M2

 

208 VAC, 3 phase input

 

M13A

 

Locking knobs for front panel controls

 

Regulatory Approvals

 

CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; UL Listed to UL3111-1; CSA certified to CSA C22.2 No 1010.1; Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard: ICES-001, Class A.

 

Note: Specifications subject to change without notice


Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

SHOP ALL PRODUCTS > Power Supplies > DC power supplies
SHOP ALL PRODUCTS > Power Supplies > DC power supplies > 2 kW DC power supplies
SHOP ALL PRODUCTS > Power Supplies > DC power supplies > 3 kW DC power supplies
SHOP ALL PRODUCTS > Brands > Sorensen
SHOP ALL PRODUCTS > Power Supplies
SHOP ALL PRODUCTS > Brands
SHOP ALL PRODUCTS


Sorensen DLM 32-95E 3040 W, 0-32 V, 0-95 A $7,238.74 US Dollars